[[email protected] ~]# ceph -s cluster: ID: 58a12719-a5ed-4f95-b312-6efd6e34e558 health: HEALTH_WARN 1 slow ops,oldest one blocked for 1416 sec,mon.node142 has slow ops services: mon: 2 daemon,quorum node140,node142 (age 8d) mgr: admin(active,since 8d),standbys: node140 mds: cephfs:1 {0=node140=up:active} 1 up:standby osd: 22 osds: 22 up (since 23m),18 in (since 29m) data: pools: 5 pools,768 pgs objects: 2.65k objects,9.9 GiB usage: 53 GiB used,12 TiB / 12 TiB avail pgs: 768 active+clean(2)检查ntpd服务
[[email protected] ~]# systemctl status ntpd[[email protected] ~]# systemctl start ntpd #新增的节点没有启动ntpd(3)重启monitor服务node140 node142 的monitor
[[email protected] ceph]# systemctl restart ceph-mon.target[[email protected] ceph]# systemctl status ceph-mon.target[[email protected] ceph]# systemctl restart ceph-mon.target[[email protected] ceph]# systemctl status ceph-mon.target(4)检查集群已经恢复
[[email protected] ceph]# ceph -s cluster: ID: 58a12719-a5ed-4f95-b312-6efd6e34e558 health: HEALTH_OK services: mon: 2 daemon,node142 (age 3m) mgr: admin(active,standbys: node140 mds: cephfs:1 {0=node140=up:active} 1 up:standby osd: 22 osds: 22 up (since 31m),18 in (since 36m) data: pools: 5 pools,12 TiB / 12 TiB avail pgs: 768 active+clean
参考:https://blog.csdn.net/genglei1022/article/details/82461053
总结以上是内存溢出为你收集整理的(11)ceph 告警:1 slow ops, oldest one blocked for全部内容,希望文章能够帮你解决(11)ceph 告警:1 slow ops, oldest one blocked for所遇到的程序开发问题。