Mysql必读从MySQL的源码剖析Innodb buffer的命中率计算

Mysql必读从MySQL的源码剖析Innodb buffer的命中率计算,第1张

概述介绍《Mysql必读从MySQL的源码剖析Innodb buffer的命中率计算》开发教程,希望对您有用。

《MysqL必读从MysqL的源码剖析Innodb buffer的命中率计算》要点:
本文介绍了MysqL必读从MysqL的源码剖析Innodb buffer的命中率计算,希望对您有用。如果有疑问,可以联系我们。
@H_419_5@

按官方手册推荐Innodb buffer Hit Ratios的计算是:
 
MysqL必读@H_419_5@

100-((iReads / iReadRequests)*100)iReads : MysqL->status->Innodb_buffer_pool_readsiReadRequests: MysqL->status->Innodb_buffer_pool_read_requests

出处: http://dev.MysqL.com/doc/MysqL-monitor/2.0/en/mem_graphref.HTML
搜”Hit Ratios”
推荐有兴趣的同学把这个页面都看一下应该也会有很大收获.
另外在HackMysqL: www.HackMysqL.com网站上的: MysqLsqlreport中关于buffer命中计算是:MysqL必读@H_419_5@

 
MysqL必读@H_419_5@

$ib_bp_read_ratio = sprintf "%.2f",($stats{'Innodb_buffer_pool_read_requests'} ?100 - ($stats{'Innodb_buffer_pool_reads'} /$stats{'Innodb_buffer_pool_read_requests'}) * 100 :0);

即: 
MysqL必读@H_419_5@

ib_bp_hit=100-(Innodb_buffer_pool_reads/Innodb_buffer_pool_read_requests)*100

另外我们知道查看Innodb Buffer Hit Ratios的地方是:
MysqL必读@H_419_5@ 代码如下:show engine innodb status\G;
Buffer pool hit rate : XXXX/1000;
那个XXX/1000即是buffer pool hit ratios的命中.
这样也可以从代码里看一下这个bp命中计算:

storage/innobase/buf/buf0buf.c # voID buf_print_iostorage/innodbase/include/buf0buf.h #struct buf_block_struct

在buf0buf.c 中的buf_print_io函数中可以看到:
 
MysqL必读@H_419_5@

voIDbuf_print_io(… if (buf_pool->n_page_gets > buf_pool->n_page_gets_old) {fprintf(file,"Buffer pool hit rate %lu / 1000\n",(ulong)(1000 - ((1000 * (buf_pool->n_pages_read- buf_pool->n_pages_read_old))/ (buf_pool->n_page_gets- buf_pool->n_page_gets_old))));} else {fputs("No buffer pool page gets since the last printout\n",file);} buf_pool->n_page_gets_old = buf_pool->n_page_gets;buf_pool->n_pages_read_old = buf_pool->n_pages_read;…}

结合:
storage\innobase\include\buf0buf.h中
MysqL必读@H_419_5@

struct buf_block_struct{…ulint n_pages_read; /* number read operations */…ulint n_page_gets; /* number of page gets performed;also successful searches throughthe adaptive hash index arecounted as page gets; this fIEldis NOT protected by the bufferpool mutex */…ulint n_page_gets_old;/* n_page_gets when buf_print waslast time called: used to calculatehit rate */…ulint n_pages_read_old;/* n_pages_read when buf_print waslast time called */…

 MysqL必读@H_419_5@


从这个来看innodb buffer hit Ratios的命中计算需要本次取的值和上次值做一个减法公式应该为
MysqL必读@H_419_5@

ib_bp_hit=1000 C (t2.iReads C t1.iReads)/(t2.iReadRequest C t1.iReadRequest)*1000

t(n): 时间点 两个时间间隔最少是30秒以上,在小意义不大.
MysqL必读@H_419_5@

iReads: Innodb_buffer_pool_readsiReadRequest: Innodb_buffer_pool_read_requests

对innodb的输出参数有兴趣的可以关注: storage/innobase/buf/Srv0srv.c 中的:
MysqL必读@H_419_5@

voID srv_export_innodb_status()

思考:
对于innodb_buffer_pool_read_requests,innodb_buffer_pool_reads这种累加值,当很大时进行: innodb_buffer_pool_reads/innodb_buffer_pool_read_requests 相来讲只能得到从开始到现在的命中率的表现了. 如果想得到现在近五分钟,近一分钟或是8点到9点每分钟的命中率情况,如果还是按着innodb_buffer_pool_reads/innodb_buffer_pool_read_requests 进行计算,只能得到MysqLd开起累计在8点-9点的每分钟的累计平均命中情况.
所以如果想到每(五)分钟的命中情况,就需要本次取得的值和一(五)分钟前的值进行相减,然后进行运算.这样才能得到一个当下的bp命中情况.
两种方法没实质的对错的问题,但相对于源码中的那种计算方式更容让发现@R_419_6948@的抖动问题.MysqL必读@H_419_5@

能解决的问题:
偶而的@R_419_6948@性能抖动能直观的反应出来.
MysqL必读@H_419_5@ 总结

以上是内存溢出为你收集整理的Mysql必读从MySQL的源码剖析Innodb buffer的命中率计算全部内容,希望文章能够帮你解决Mysql必读从MySQL的源码剖析Innodb buffer的命中率计算所遇到的程序开发问题。

如果觉得内存溢出网站内容还不错,欢迎将内存溢出网站推荐给程序员好友。

欢迎分享,转载请注明来源:内存溢出

原文地址: http://outofmemory.cn/sjk/1163332.html

(0)
打赏 微信扫一扫 微信扫一扫 支付宝扫一扫 支付宝扫一扫
上一篇 2022-06-01
下一篇 2022-06-01

发表评论

登录后才能评论

评论列表(0条)

保存